Lift, Escalator and Passenger Conveyor Regulations, 2010
69 rows
Not verified⚑ 0 flags open
| Flag | Citation | Number | Subs | Para | Subpara | Item | Role | Text |
|---|---|---|---|---|---|---|---|---|
| Lift, Escalator and Passenger Conveyor Regulations 1 | 1 | opening | In these Regulations any word or expression to which a meaning has been assigned in the Act shall have the meaning so assigned and, unless the context otherwise indicates— | |||||
| Lift, Escalator and Passenger Conveyor Regulations 2(1) | 2 | (1) | entry | These Regulations shall apply to employers or self employed persons who carry out work on lifts, escalators or passenger conveyors. | ||||
| Lift, Escalator and Passenger Conveyor Regulations 2(2) | 2 | (2) | entry | These Regulations shall apply to persons who have on their premises either permanently lifts, escalators or passenger conveyors. | ||||
| Lift, Escalator and Passenger Conveyor Regulations 3(1) | 3 | (1) | opening | No person shall install or permit the installation of a new or used lift, escalator or passenger conveyor unless— | ||||
| Lift, Escalator and Passenger Conveyor Regulations 3(1)(a) | 3 | (1) | (a) | entry | that person has submitted a completed form in the form of Annexure 1 to the relevant provincial director who shall allocate an official number to the lift, escalator or passenger conveyor; | |||
| Lift, Escalator and Passenger Conveyor Regulations 3(1)(b) | 3 | (1) | (b) | entry | that person has been allocated an official number contemplated in paragraph (a); and | |||
| Lift, Escalator and Passenger Conveyor Regulations 3(1)(c) | 3 | (1) | (c) | entry | such installation meets the requirements of these Regulations and complies with the relevant standards and specifications incorporated into these Regulations under section 44 of the Act. | |||
| Lift, Escalator and Passenger Conveyor Regulations 3(2) | 3 | (2) | entry | No person shall put into use or require or permit the use of a lift, escalator or passenger conveyor unless that person is in possession of a valid comprehensive report issued in terms of regulation 6 (4): | ||||
| Lift, Escalator and Passenger Conveyor Regulations 3(2) | 3 | (2) | proviso | Provided that such report shall be completed by an inspection service provider. | ||||
| Lift, Escalator and Passenger Conveyor Regulations 3(3) | 3 | (3) | entry | The user of a lift that does not operate automatically shall appoint the operator of such a lift in writing and instruct that operator as to the dangers of its operation. | ||||
| Lift, Escalator and Passenger Conveyor Regulations 4(1) | 4 | (1) | opening | Subject to regulation 3 (2), no person shall use, install or modify, or permit the use, installation or modification, of any lift, escalator or passenger conveyor unless— | ||||
| Lift, Escalator and Passenger Conveyor Regulations 4(1)(a) | 4 | (1) | (a) | entry | such lift, escalator or passenger conveyor has been designed and constructed or modified in accordance with the relevant standard incorporated for this purpose into these Regulations under section 44 of the Act; and | |||
| Lift, Escalator and Passenger Conveyor Regulations 4(1)(b) | 4 | (1) | (b) | entry | the requirements of the National Building Regulations, if applicable, have been complied with. | |||
| Lift, Escalator and Passenger Conveyor Regulations 4(2) | 4 | (2) | entry | The user shall ensure that all the electrical components of a lift, escalator or passenger conveyor which is installed in a location where there is a danger of fire or explosion due to the presence, occurrence or development of explosive or flammable atmospheres or where explosive articles are manufactured, handled or stored, comply with regulation 8 of the Electrical Machinery Regulations, 1988, promulgated by Government Notice No. R.1593 of 12 August 1988, as well as the Explosives Regulations, promulgated by Government Notice No. R.109 of 17 January 2003. | ||||
| Lift, Escalator and Passenger Conveyor Regulations 5(1) | 5 | (1) | opening | The user shall ensure that every lift, escalator and passenger conveyor is marked, in the machine compartment, in a conspicuous place, within a holder, with the following particulars: | ||||
| Lift, Escalator and Passenger Conveyor Regulations 5(1)(a) | 5 | (1) | (a) | entry | The name of the manufacturer; | |||
| Lift, Escalator and Passenger Conveyor Regulations 5(1)(b) | 5 | (1) | (b) | entry | the year of installation; | |||
| Lift, Escalator and Passenger Conveyor Regulations 5(1)(c) | 5 | (1) | (c) | entry | the year of modification; | |||
| Lift, Escalator and Passenger Conveyor Regulations 5(1)(d) | 5 | (1) | (d) | entry | the official number contemplated in regulation 3 (1) (a); | |||
| Lift, Escalator and Passenger Conveyor Regulations 5(1)(e) | 5 | (1) | (e) | entry | the rated speed in metres per second; and | |||
| Lift, Escalator and Passenger Conveyor Regulations 5(1)(f) | 5 | (1) | (f) | entry | the rated load in kilograms. | |||
| Lift, Escalator and Passenger Conveyor Regulations 5(2) | 5 | (2) | entry | Where the machinery of more than one lift, escalator or passenger conveyor is installed in a compartment, the user shall ensure that all the machinery and switch-gear of each unit are distinctly and permanently marked with the same distinguishing mark, which shall differ from the distinguishing mark of the machinery and switchgear of any other unit in that compartment. | ||||
| Lift, Escalator and Passenger Conveyor Regulations 5(3) | 5 | (3) | entry | The user shall keep an up-to-date, legible and schematic electrical wiring diagram in respect of every lift, escalator or passenger conveyor in a safe place in the machine compartment, as the case may be. | ||||
| Lift, Escalator and Passenger Conveyor Regulations 5(4) | 5 | (4) | entry | The user shall affix or cause to be affixed in a conspicuous place at the main landing of every group of lifts and in each car and at every group of escalators and passenger conveyors, the name and telephone number of the competent lift service provider designated in terms of regulation 7 (1). | ||||
| Lift, Escalator and Passenger Conveyor Regulations 6(1) | 6 | (1) | opening | The user shall ensure that every lift, escalator or passenger conveyor is inspected and tested in accordance with the relevant health and safety standards incorporated into these Regulations under section 44 of the Act— | ||||
| Lift, Escalator and Passenger Conveyor Regulations 6(1)(a) | 6 | (1) | (a) | entry | before such lift, escalator or passenger conveyor is put into use for the first time; or | |||
| Lift, Escalator and Passenger Conveyor Regulations 6(1)(b) | 6 | (1) | (b) | entry | after any modification has been effected; or | |||
| Lift, Escalator and Passenger Conveyor Regulations 6(1)(c) | 6 | (1) | (c) | entry | after any failure has occurred; or | |||
| Lift, Escalator and Passenger Conveyor Regulations 6(1)(d) | 6 | (1) | (d) | entry | whenever there has been a change in the competent lift service provider; and | |||
| Lift, Escalator and Passenger Conveyor Regulations 6(1)(e) | 6 | (1) | (e) | entry | at intervals not exceeding 24 months thereafter, or at shorter intervals according to in-house risk assessment, | |||
| Lift, Escalator and Passenger Conveyor Regulations 6(1) | 6 | (1) | closing | by an inspection service provider who shall complete a comprehensive report separately for each lift, escalator or passenger conveyor so inspected and tested, and such inspection service provider shall date and sign such report and submit it within 30 days to the user, who shall keep the report in a safe place and a copy of the report in the machine compartment. | ||||
| Lift, Escalator and Passenger Conveyor Regulations 6(2) | 6 | (2) | entry | If an inspection or test carried out by an inspection service provider on a lift, escalator or passenger conveyor shows that any defect or weakness exists whereby persons are endangered, the inspection service provider shall report such defect or weakness forthwith to the user, the competent lift service provider and the provincial director, and no person shall be conveyed or allowed to be conveyed in or on such lift, escalator or passenger conveyor until such defect has been rectified to the satisfaction of the inspection service provider. | ||||
| Lift, Escalator and Passenger Conveyor Regulations 6(3) | 6 | (3) | entry | If a comprehensive report in accordance with a health and safety standard incorporated into these Regulations under section 44 of the Act shows a defect or weakness not considered under subregulation (2) the user shall rectify such defect or weakness. | ||||
| Lift, Escalator and Passenger Conveyor Regulations 6(4) | 6 | (4) | opening | A comprehensive report for a lift, escalator or passenger conveyor shall be completed when— | ||||
| Lift, Escalator and Passenger Conveyor Regulations 6(4)(a) | 6 | (4) | (a) | entry | the lift, escalator or conveyor is put into use for the first time; | |||
| Lift, Escalator and Passenger Conveyor Regulations 6(4)(b) | 6 | (4) | (b) | entry | any modification to the lift, escalator or conveyor has been effected; | |||
| Lift, Escalator and Passenger Conveyor Regulations 6(4)(c) | 6 | (4) | (c) | entry | a reportable incident in terms of section 24 of the Act occurs; | |||
| Lift, Escalator and Passenger Conveyor Regulations 6(4)(d) | 6 | (4) | (d) | entry | there is a change in the designated competent lift service provider; and | |||
| Lift, Escalator and Passenger Conveyor Regulations 6(4)(e) | 6 | (4) | (e) | entry | at intervals not exceeding 24 months thereafter. | |||
| Lift, Escalator and Passenger Conveyor Regulations 6(5) | 6 | (5) | entry | When an inspection or a test is conducted by an inspection service provider the inspection service provider shall ensure that all the documents and records required in terms of regulation 8 are kept in good order and are up to date. | ||||
| Lift, Escalator and Passenger Conveyor Regulations 6(6) | 6 | (6) | entry | An inspector may at any reasonable time inspect any lift, escalator or passenger conveyor, and the user shall place, free of charge, at the disposal of the inspector any workmen and equipment that may be reasonably required by the inspector for the purpose of carrying out such inspection. | ||||
| Lift, Escalator and Passenger Conveyor Regulations 6(7) | 6 | (7) | entry | An inspection service provider who wishes to avail himself or herself of designation as such by the user of a lift, escalator or passenger conveyor in order to carry out an inspection in terms of this regulation shall register with the accreditation authority. | ||||
| Lift, Escalator and Passenger Conveyor Regulations 7(1) | 7 | (1) | entry | The user shall designate a competent lift service provider to examine and maintain a lift, escalator or passenger conveyor at least once a month or at such longer intervals as may be prescribed by the manufacturer of such lift, escalator or passenger conveyor: | ||||
| Lift, Escalator and Passenger Conveyor Regulations 7(1) | 7 | (1) | proviso | Provided that an inspector may prescribe such examining intervals as he or she may deem necessary. | ||||
| Lift, Escalator and Passenger Conveyor Regulations 7(2) | 7 | (2) | entry | At an examination contemplated in subregulation (1), the competent lift service provider shall examine the parts of a lift, escalator or passenger conveyor as prescribed by the relevant manufacturer or by an inspector: | ||||
| Lift, Escalator and Passenger Conveyor Regulations 7(2) | 7 | (2) | proviso | Provided that in the case of a lift, he or she shall test all the gates and door locks at each examination: | ||||
| Lift, Escalator and Passenger Conveyor Regulations 7(2) | 7 | (2) | proviso | Provided further that the suspension ropes of a lift shall be examined at six-monthly intervals and that the lift safety gear, over speed governor and buffers shall be tested at intervals not exceeding 12 months. | ||||
| Lift, Escalator and Passenger Conveyor Regulations 7(3) | 7 | (3) | entry | If maintenance or an examination carried out in terms of subregulation (1) or a test carried out in terms of subregulation (2) shows that a weakness or defect exists whereby persons are endangered, the competent lift service provider shall report the weakness or defect immediately to the user and the provincial director, and no person shall be conveyed in or allowed to be conveyed in or on such lift, escalator or passenger conveyor or to enter such access goods only lift until such defect has been rectified to the satisfaction of an inspection service provider. | ||||
| Lift, Escalator and Passenger Conveyor Regulations 7(4) | 7 | (4) | entry | The user of a lift, escalator or passenger conveyor shall immediately take steps to stop the working thereof and to prevent the starting thereof if its use is or is likely to be dangerous to persons. | ||||
| Lift, Escalator and Passenger Conveyor Regulations 7(5) | 7 | (5) | entry | The user of a lift, escalator or passenger conveyor and the competent lift service provider responsible for the examinations contemplated in subregulation (1) or test contemplated in subregulation (2) shall immediately notify the provincial director in writing of the name and address of the competent lift service provider carrying out such examinations or tests. | ||||
| Lift, Escalator and Passenger Conveyor Regulations 7(6) | 7 | (6) | entry | The competent lift service provider shall notify the provincial director and the user immediately in writing if a lift, escalator or passenger conveyor is found to be in operation without a valid comprehensive report issued in terms of regulation 6 that is kept in the machine compartment in terms of regulation 8. | ||||
| Lift, Escalator and Passenger Conveyor Regulations 8(1) | 8 | (1) | opening | The user of a lift, escalator or passenger conveyor shall keep in a safe place in the machine compartment of every such lift, escalator or passenger conveyor a record in which he or she shall enter or cause to be entered— | ||||
| Lift, Escalator and Passenger Conveyor Regulations 8(1)(a) | 8 | (1) | (a) | entry | his or her name, address and telephone number | |||
| Lift, Escalator and Passenger Conveyor Regulations 8(1)(b) | 8 | (1) | (b) | entry | the name, address and telephone number of the competent lift service provider designated by him or her to carry out the maintenance and examinations contemplated in regulation 7 (1) and the tests contemplated in regulation 7 (2); | |||
| Lift, Escalator and Passenger Conveyor Regulations 8(1)(c) | 8 | (1) | (c) | entry | a report on the results of every examination contemplated in regulation 7 (1), and the test contemplated in regulation 7 (2) including any modifications, repairs, adjustments and tests carried out; | |||
| Lift, Escalator and Passenger Conveyor Regulations 8(1)(d) | 8 | (1) | (d) | entry | a copy of the latest comprehensive report contemplated in regulation 6 (4); | |||
| Lift, Escalator and Passenger Conveyor Regulations 8(1)(e) | 8 | (1) | (e) | entry | a copy of all suspension rope certificates and the results of the examination contemplated in regulation 7 (2) on the condition of the suspension ropes; | |||
| Lift, Escalator and Passenger Conveyor Regulations 8(1)(f) | 8 | (1) | (f) | entry | the registers or files and the technical dossiers required in terms of the relevant SANS specifications; | |||
| Lift, Escalator and Passenger Conveyor Regulations 8(1)(g) | 8 | (1) | (g) | entry | the commissioning acceptance report or copy thereof required in terms of the relevant SANS specification; and | |||
| Lift, Escalator and Passenger Conveyor Regulations 8(1)(h) | 8 | (1) | (h) | entry | a copy of each comprehensive report made in respect of incidents in terms of section 24 (1) (c) (iii) and (iv) of the Act. | |||
| Lift, Escalator and Passenger Conveyor Regulations 8(2) | 8 | (2) | entry | The user shall keep the records contemplated in subregulation (1) in the relevant machine compartment for a period of at least 10 years. | ||||
| Lift, Escalator and Passenger Conveyor Regulations 9(1) | 9 | (1) | entry | An inspection service provider who wishes to avail himself or herself of designation as such by the user of a lift, escalator or passenger conveyor in order to carry out an inspection in terms of regulation 6, shall register with the accreditation authority. | ||||
| Lift, Escalator and Passenger Conveyor Regulations 9(2) | 9 | (2) | entry | The Chief Inspector may at any time withdraw any approval of an approved inspection authority, subject to section 35 of the Act. | ||||
| Lift, Escalator and Passenger Conveyor Regulations 10 | 10 | entry | Any person who contravenes or fails to comply with any provision of regulation 3 (1), 3 (2), 3 (3),4 (1),4 (2), 5 (1), 5 (2), 5 (3), 5 (4), 6 (1), 6 (2), 6 (3), 6 (4), 6 (5), 6 (6), 6 (7), 7 (1), 7 (2), 7 (3),7 (4), 7 (5), 7 (6), 8 (1), 8 (2) or 9 (1) shall be guilty of an offence and liable upon conviction to a fine or to imprisonment for a maximum of 12 months and, in the case of a continuous offence, to an additional fine of R200,00 for each day on which the offence continues or to additional imprisonment of one day for each day on which the offence continues: | |||||
| Lift, Escalator and Passenger Conveyor Regulations 10 | 10 | proviso | Provided that the period of such additional imprisonment shall not exceed 90 days. | |||||
| Lift, Escalator and Passenger Conveyor Regulations 11(1) | 11 | (1) | entry | The Lift, Escalator and Passenger Conveyor Regulations promulgated by Government Notice No. R.797 of 29 April 1994 are hereby repealed. | ||||
| Lift, Escalator and Passenger Conveyor Regulations 11(2) | 11 | (2) | entry | Lifts installed or modified prior to 1 May 1994 shall be considered to comply with regulation 4 (1) | ||||
| Lift, Escalator and Passenger Conveyor Regulations 12 | 12 | entry | These regulations shall be called the Lift, Escalator and Passenger Conveyor Regulations, 2010, and shall come into effect on 30 November 2010. | |||||
| Lift, Escalator and Passenger Conveyor Regulations 12 | 12 | proviso | Provided that regulation 6 (7) shall come into effect on 1 December 2012. |