Pressure Equipment Regulations 9 Pressure equipment marking

20 rows

Not verified⚑ 0 flags open
FlagCitationNumberSubsParaSubparaItemRoleText
Subsection (1)
Pressure Equipment Regulations 9(1)9(1)entry
Every manufacturer of pressure equipment shall cause the pressure equipment to be marked in accordance with the relevant health and safety standard incorporated into these Regulations under section 44 of the Act.
Subsection (2)
Pressure Equipment Regulations 9(2)9(2)opening
Every manufacturer shall cause a data plate to be permanently fixed in a conspicuous place to any steam generator or pressure vessel with the following minimum particulars:
Pressure Equipment Regulations 9(2)(a)9(2)(a)entry
name of manufacturer;
Pressure Equipment Regulations 9(2)(b)9(2)(b)entry
country of origin;
Pressure Equipment Regulations 9(2)(c)9(2)(c)entry
year of manufacture;
Pressure Equipment Regulations 9(2)(d)9(2)(d)entry
manufacturer’s serial number;
Pressure Equipment Regulations 9(2)(e)9(2)(e)entry
reference number, date and edition of the health and safety standard;
Pressure Equipment Regulations 9(2)(f)9(2)(f)entry
design pressure in units of Pascal;
Pressure Equipment Regulations 9(2)(g)9(2)(g)entry
design temperature for both minimum and maximum in degrees Celsius;
Pressure Equipment Regulations 9(2)(h)9(2)(h)entry
capacity in cubic metres;
Pressure Equipment Regulations 9(2)(i)9(2)(i)entry
unique mark of an approved inspection authority as applicable; and
Pressure Equipment Regulations 9(2)(j)9(2)(j)entry
the hazard category in accordance with the requirements of SANS 347.
Subsection (3)
Pressure Equipment Regulations 9(3)9(3)opening
In the case of composite pressure equipment the following information shall be included in addition to that referred to in subregulation (2):
Pressure Equipment Regulations 9(3)(a)9(3)(a)entry
the resin system of the corrosion barrier/lining;
Pressure Equipment Regulations 9(3)(b)9(3)(b)entry
the resin system of the structural wall; and
Pressure Equipment Regulations 9(3)(c)9(3)(c)entry
the name and specific gravity of the medium for which the vessel was designed.
Subsection (4)
Pressure Equipment Regulations 9(4)9(4)entry
No person may remove a marking or data plate referred to in this regulation or wilfully damage or alter the particulars marked thereon, except as provided in this regulation.
Subsection (5)
Pressure Equipment Regulations 9(5)9(5)entry
A user shall ensure that any modification that changes the original design conditions is identified by affixing an additional data plate.
Subsection (6)
Pressure Equipment Regulations 9(6)9(6)entry
A user shall ensure that a data plate is affixed to any steam generator or pressure vessel that has been re-certified:
Pressure Equipment Regulations 9(6)9(6)proviso
Provided that where the manufacturer is unknown, the user responsible for the re-certification shall be deemed to be the manufacturer.