Physical Agents Regulations 9 Cold stress

19 rows

✓ Verified on 2026-11-17⚑ 0 flags open
FlagCitationNumberSubsParaSubparaItemRoleText
Subsection (1)
Physical Agents Regulations 9(1)9(1)entry
The employer or self-employed person must ensure that cold stress is eliminated at the source, where reasonably practicable.
Subsection (2)
Physical Agents Regulations 9(2)9(2)opening
Where the provision of subregulation (1) is not reasonably practicable and exposure is at or below the OEL stipulated in Table 1, the employer or self-employed person must, as a minimum—
Physical Agents Regulations 9(2)(a)9(2)(a)entry
implement alternative working methods to reduce exposure to cold stress;
Physical Agents Regulations 9(2)(b)9(2)(b)entry
install plant and machinery designed to reduce the risk of cold stress, where applicable;
Physical Agents Regulations 9(2)(c)9(2)(c)entry
implement maintenance programmes for plant and machinery, the workplace and workplace systems;
Physical Agents Regulations 9(2)(d)9(2)(d)entry
review the design and layout of workplaces, workstations and rest facilities;
Physical Agents Regulations 9(2)(e)9(2)(e)opening
review the—
Physical Agents Regulations 9(2)(e)(i)9(2)(e)(i)entry
physical agent exposure risk assessment;
Physical Agents Regulations 9(2)(e)(ii)9(2)(e)(ii)entry
physical agent exposure monitoring programme;
Physical Agents Regulations 9(2)(e)(iii)9(2)(e)(iii)entry
medical screening;
Physical Agents Regulations 9(2)(e)(iv)9(2)(e)(iv)entry
medical surveillance; and
Physical Agents Regulations 9(2)(e)(v)9(2)(e)(v)entry
control measures;
Physical Agents Regulations 9(2)(f)9(2)(f)entry
limit the duration and magnitude of exposure of employees such as to not exceed the periods as stipulated in Table 8; and
Physical Agents Regulations 9(2)(g)9(2)(g)entry
provide an employee with dry, whole-body personal protective clothing and equipment with adequate insulation.
Subsection (3)
Physical Agents Regulations 9(3)9(3)opening
The physical agent exposure monitoring programme must—
Physical Agents Regulations 9(3)(a)9(3)(a)entry
take into account both the dry-bulb temperature and air velocity when determining the time-weighted average environmental equivalent chill temperature;
Physical Agents Regulations 9(3)(b)9(3)(b)entry
be taken over a period of at least 4-hours;
Physical Agents Regulations 9(3)(c)9(3)(c)entry
be conducted during the coldest period of an employee’s shift; and
Physical Agents Regulations 9(3)(d)9(3)(d)entry
be conducted during the coldest quarter of the year as determined by the physical agent exposure risk assessment.